Using hardware diagnostics, Using post diagnostics, Using offline diagnostics – Brocade Network OS Administrator’s Guide v4.1.1 User Manual

Page 721

background image

ASICs and ports

TABLE 105

Network OS
switch

ASIC

Port numbers

Brocade VDX
6720-60 and
Brocade VDX
6730-76

0

te0/1 through te0/10

1

te0/11 through te0/20

2

te0/21 through te0/30

3

te0/31 through te0/40

4

te0/41 through te0/50

5

te0/51 through te0/60

Brocade VDX
6710

0

te0/1 through te0/6 and gi0/1 through gi0/14

1

gi0/15 through gi0/27

2

gi0/28 through gi0/48

The destination port cannot be an ISL, Layer 2, Layer 3, QoS, ACL, 802.1x, LAG member, LLDP, or
port-profile port. The source port cannot be an ISL port. In VCS Fabric mode, only edge ports are
eligible for mirroring.

Using hardware diagnostics

The following diagnostic types currently exist:

• Power-on self-test (POST)
• Offline diagnostics

Online diagnostics are not currently supported on Brocade VDX switches.

Using POST diagnostics

POST is run on bootup and the results are stored. Use the show diag post results command to view
the stored results.

To enable POST, enter the diag post rbridge-id rbridge-id enable command.

Using offline diagnostics

Before proceeding, note the following Caution:

CAUTION
Offline diagnostics — otherwise known as system verification tests — are disruptive tests that
check the individual hardware components thoroughly and report the findings. You must
disable the chassis before running these tests. Do not run production traffic during this time.

Enter the diag systemverification command to run the entire set of offline diagnostics. This command
can take up to two hours to finish, so Brocade recommends the less disruptive diag systemverification

Using hardware diagnostics

Network OS Administrator’s Guide

721