beautypg.com

IAI America TT-C3 User Manual

Page 88

background image

78

INTELLIGENT ACTUATOR

Chapter 4 Commands

1.

List

of

SEL

Language

Command

Codes

by

Function

Operation type in the output field
CC: Command was executed successfully, ZR: Operation result is zero,
PE: Operation is complete, CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1 Operand 2,
GT: Operand 1 > Operand 2, GE: Operand 1

Operand 2,

LT:

Operand 1 < Operand 2, LE: Operand 1 Operand 2

Category

Condition

Command

Operand 1

Operand 2

Output

Function

Page

Optional

BGPA

Palletizing number

Prohibited

CP

Declare start of palletizing setting

201

Prohibited

EDPA

Prohibited

Prohibited

CP

Declare end of palletizing setting

201

Optional

PAPI

Count

Count

CP

Set palletizing counts

202

Optional

PAPN

Pattern number

Prohibited

CP

Set palletizing pattern

202

Optional

PASE

Axis number

Axis number

CP

Set palletizing axes

203

Optional

PAPT

Pitch

Pitch

CP

Set palletizing pitches

203

Optional

PAST

(Position number)

Prohibited

CP

Set palletizing reference point

204

Optional

PAPS

Position number

Prohibited

CP

Set 3 palletizing points for
teaching

205

Optional

PSLI

Offset amount

(Count)

CP

Set zigzag

206

Optional

PCHZ

(Axis number)

Prohibited

CP

Set palletizing Z-axis

207

Optional

PTRG

Position number

Position number

CP

Set palletizing arch triggers

208

Optional

PEXT

(Position number)

Prohibited

CP

Set palletizing composition

209

Optional

OFPZ

Offset amount

Prohibited

CP

Set palletizing Z-axis offset

209

Optional

ACHZ

Axis number

Prohibited

CP

Declare arch-motion Z-axis

210

Optional

ATRG

Position number

Position number

CP

Set arch triggers

211

Optional

AEXT

(Position number)

Prohibited

CP

Set arch-motion composition

212

Optional

OFAZ

Offset amount

Prohibited

CP

Set arch-motion Z-axis offset

212

Optional

PTNG

Palletizing number

Variable number

CP

Get palletizing position number

213

Optional

PINC

Palletizing number

Prohibited

CC

Increment palletizing position
number by 1

213

Optional

PDEC

Palletizing number

Prohibited

CC

Decrement palletizing position
number by 1

214

Optional

PSET

Palletizing number

Data

CC

Set palletizing position number
directly

214

Optional

PARG

Palletizing number

Axis number

CP

Get palletizing angle

215

Optional

PAPG

Palletizing number

Position number

CP

Get palletizing calculation data

215

Optional

PMVP

Palletizing number

(Position number)

PE

Move to palletizing points via PTP

216

Optional

PMVL

Palletizing number

(Position number)

PE

Move to palletizing points via
interpolation

217

Optional

PACH

Palletizing number

Position number

PE

Palletizing-point arch motion

218

Palletizing-

related

Optional

ARCH

Position number

Position number

PE

Arch motion

220

Extension conditions LD (LOAD), A (AND), O (OR), AB (AND BLOCK) and OB (OR BLOCK) are supported.

Optional

CHPR

0 or 1

Prohibited

CP

Change task level

222

Prohibited

TPCD

0 or 1

Prohibited

CP

Specify processing to be
performed when input condition is
not specified

222

Prohibited

TSLP

Time

Prohibited

CP

Task sleep

223

Optional

OUTR

Output, flag number

Prohibited

CP

Output relay for ladder

See

245

Building of

pseudo-

ladder task

Optional

TIMR

Local flag number

Timer setting

CP

Timer relay for ladder

See

245

This manual is related to the following products: