71

INTELLIGENT ACTUATOR

Chapter 3 X

SEL Lanhuage Data

2.
Position

Part

X-SEL language consists of a position part (position data = coordinates, etc.) and a command part
(application program).

2. Position

Part

As position data, coordinates, speeds, accelerations and decelerations are set and stored.

* If speed, acceleration or deceleration is set in the position data, the setting will be given priority

over the corresponding data set in the application program. Leave the position data fields
empty if you wish to enable the corresponding data in the application program.

The effective speed and acceleration are determined based on the following priorities.

Priority

Speed

Acceleration (deceleration)

1

Position data value set in operand 1

Position data value set in operand 1

2

Value set by a VEL command

Value set by an ACC (DCL) command

3

All-axis parameter No. 11, “Default acceleration”
(All-axis parameter No. 12, “Default deceleration”)

Position No. Axis 1 Axis 2 Axis 3 Speed

Acceleration

Deceleration

1 to 300/mm sec

* Maximum

Gate type: 0.3 G
Cantilever type: 0.2 G

* Maximum

Gate type: 0.3 G
Cantilever type: 0.2 G

This manual is related to the following products: