326
INTELLIGENT ACTUATOR
Appendix
Appendix
(In the panel
wind
ow, the three di
gits after “E” in
dicate an error n
u
m
ber.)
Erro
r No.
Erro
r name
De
scription, a
c
tion, etc.
B1F
Ethernet job
busy error
An attempt was made to st
art a new process
when the Ethernet m
a
ilbox
control job was busy.
B20
Ethernet non-initialization device use error
An attempt was mad
e to use the Ethernet system when Ethernet device
initialization
was not yet complete.
Check I/O parameter Nos. 123 to
159, 14, 15, etc., dependi
ng on the purpose of use.
B21
Ethernet IP address error
An error will generate un
der the following condition
s during normal
use.
When IP address (H) (first octet) th
roug
h IP addre
ss
(L)
(fourth o
c
tet)
are given a
s
IP_H, IP_MH, IP_ML
and IP_L, the error
conditions are
descri
bed as
follows:
IP_H
d
0 or I
P
_H = 12
7 or IP_H > 255
or IP_MH
< 0
or IP_MH >
255
or IP_ML < 0
or IP_ML > 2
55
or IP_L
d
0 or IP_L
t
255
Check I/O parameter Nos.
132 to 135,
149 to 152, and 154 to 157, the
IP addre
ss of
conn
ectio
n d
estinatio
n sp
ecified by an
IPCN command in
an integer variable, or the li
ke.
B22
Ethernet port number error
An error
will generate if own port num
be
r < 10
25, or o
w
n po
rt numb
er >
6553
5, or own port num
be
r dupli
cation,
or co
nne
ction
-de
stination p
ort
numbe
r for cli
ent
d
0, or connection-destination po
rt numbe
r for clie
nt >
6553
5, or co
n
nectio
n-d
esti
nation po
rt nu
mber fo
r se
rver < 0, or
connection-destination port number fo
r server > 65535 is satisfied.
Check I/O parameter Nos.
144 to 148, 159, 153, and
158, the port
numbe
r of co
nne
ction de
st
ination sp
e
c
ified by an IPCN com
man
d in an
integer variable, or the like.
C02
Executable p
rogra
m co
unt over erro
r
Execution req
uest
s we
re re
ceived for p
rogram
s excee
ding the num
ber
that can be e
x
ecuted
simul
taneou
sly.
C03
Non-regi
stered program
specification erro
r
The sp
ecifie
d
prog
ram is n
ot registe
re
d.
C04
Program entry point non-d
etection e
rror
A reque
st
wa
s made to ex
ecute a p
rog
ram numb
er for whi
ch n
o
prog
ram step
s
are regi
stered.
C05
Program first
-step BGSR e
rro
r
The program spe
cified for
execution starts with BGS
R.
C06
Executable
step non
-dete
ct
ion error
The program
spe
cified for
execution does not contai
n executable
prog
ram step
s.
C07
Subro
utine n
on-d
efinition
error
The su
broutine specified for call is not defined.
C08 Subroutine
duplicate-defini
tion error
The same subroutine num
ber is defined at multiple locations.
C0A
Tag dupli
cate-definition error
The same
tag number is defined at multiple locations.
C0B
Tag non
-d
efinition error
The tag speci
fied as
the jump destination of a GOTO
statement i
s
not
defined.