Other Parameters
No Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
21
Manual mode type
0
0 to 5
0: Always enable edit and SIO/PIO start (Initial condition
after connection = With safety speed)
1: Select edit and start (with password) (EU, etc.)
2: Always enable edit and SIO/PIO start (Initial condition
after connection = Without safety speed (cancellation))
(PC software version 1.1.0.7 or later and TP application
version 1.06 or later)
* Referenced by the PC/TP.
22
Control use region
0
0 to 99
0: J, 1: E, 2: EU
23
PSIZ command function type
0
0 to 5
0: Maximum number of point data areas
1: Number of point data used
24
Local variable number for
storing SEL communication
command return code
99
1 to 99
1001 to 1099
25 to
29
(For expansion)
0
30
Option Password 00
0H
0H to
FFFFFFFFH
HOME command option (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
31
Option Password 01
0H
0H to
FFFFFFFFH
Reserved (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
32
Option Password 02
0H
0H to
FFFFFFFFH
Reserved (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
33 to
35
(For expansion)
0H
0H to
FFFFFFFFH
36
PC/TP data protect setting
(Program)
0H
0H to
FFFFFFFFH
Bits 0 to 3:
Protect type (0: Read/write, 1: Read only,
2: No read/write)
Bits 4 to 7:
Protect release method (0: Special
operation)
Bits 8 to 11:
Protect range maximum number (1’s place,
BCD)
Bits 12 to 15:
Protect range maximum number (10’s
place, BCD)
Bits 16 to 19:
Protect range minimum number (1’s place,
BCD)
Bits 20 to 23:
Protect range minimum number (10’s
place, BCD)
* Referenced by the PC/TP (PC software version 2.0.0.42
or later and TP application version 1.09 or later)
37
PC/TP data protect setting
(Position)
0H
0H to
FFFFFFFFH
Bits 0 to 3:
Protect type (0: Read/write, 1: Read only,
2: No read/write)
Bits 4 to 7:
Protect release method (0: Special
operation)
Bits 8 to 11:
Protect range maximum number (10’s
place, BCD)
Bits 12 to 15:
Protect range maximum number (100’s
place, BCD)
Bits 16 to 19:
Protect range maximum number (1000’s
place, BCD)
Bits 20 to 23:
Protect range minimum number (10’s
place, BCD)
Bits 24 to 27:
Protect range minimum number (1000’s
place, BCD)
* The value in the 1’s place is considered “0” for both the
protect range maximum/minimum numbers.
* Referenced by the PC/TP (PC software version 2.0.0.42
or later and TP application version 1.09 or later)
PC: PC software
TP: Teaching pendant