311

INTELLIGENT ACTUATOR

Appendix

Appendix

Other Parameters

No Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

21

Manual mode type

0

0 to 5

0: Always enable edit and SIO/PIO start (Initial condition

after connection = With safety speed)

1: Select edit and start (with password) (EU, etc.)
2: Always enable edit and SIO/PIO start (Initial condition

after connection = Without safety speed (cancellation))
(PC software version 1.1.0.7 or later and TP application
version 1.06 or later)

* Referenced by the PC/TP.

22

Control use region

0

0 to 99

0: J, 1: E, 2: EU

23

PSIZ command function type

0

0 to 5

0: Maximum number of point data areas
1: Number of point data used

24

Local variable number for
storing SEL communication
command return code

99

1 to 99

1001 to 1099

25 to

29

(For expansion)

0

30

Option Password 00

0H

0H to

FFFFFFFFH

HOME command option (Change prohibited)
* Change is prohibited unless instructed by the

manufacturer.

31

Option Password 01

0H

0H to

FFFFFFFFH

Reserved (Change prohibited)
* Change is prohibited unless instructed by the

manufacturer.

32

Option Password 02

0H

0H to

FFFFFFFFH

Reserved (Change prohibited)
* Change is prohibited unless instructed by the

manufacturer.

33 to

35

(For expansion)

0H

0H to

FFFFFFFFH

36

PC/TP data protect setting
(Program)

0H

0H to

FFFFFFFFH

Bits 0 to 3:

Protect type (0: Read/write, 1: Read only,
2: No read/write)

Bits 4 to 7:

Protect release method (0: Special
operation)

Bits 8 to 11:

Protect range maximum number (1’s place,
BCD)

Bits 12 to 15:

Protect range maximum number (10’s
place, BCD)

Bits 16 to 19:

Protect range minimum number (1’s place,
BCD)

Bits 20 to 23:

Protect range minimum number (10’s
place, BCD)

* Referenced by the PC/TP (PC software version 2.0.0.42

or later and TP application version 1.09 or later)

37

PC/TP data protect setting
(Position)

0H

0H to

FFFFFFFFH

Bits 0 to 3:

Protect type (0: Read/write, 1: Read only,
2: No read/write)

Bits 4 to 7:

Protect release method (0: Special
operation)

Bits 8 to 11:

Protect range maximum number (10’s
place, BCD)

Bits 12 to 15:

Protect range maximum number (100’s
place, BCD)

Bits 16 to 19:

Protect range maximum number (1000’s
place, BCD)

Bits 20 to 23:

Protect range minimum number (10’s
place, BCD)

Bits 24 to 27:

Protect range minimum number (1000’s
place, BCD)

* The value in the 1’s place is considered “0” for both the

protect range maximum/minimum numbers.

* Referenced by the PC/TP (PC software version 2.0.0.42

or later and TP application version 1.09 or later)

PC: PC software
TP: Teaching pendant