Parameters common to all axes – IAI America TT-C3 User Manual
Page 307

297
INTELLIGENT ACTUATOR
Appendix
Appendix
2. Parameters Common to All Axes
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
1
Effective axis pattern
0000B
00B to
11111111B
2
Default override
100
1 to 100
Used if not specified in program. (Invalid for SIO operation)
3 to 8 (For expansion)
0
9 Deadman-switch
enabling
physical axis pattern
11111111B 00B
to
11111111B
Not affected by a BASE command. (Always specify 11111111
if all axes are used. If not, the servo may be turned off only for
the specified axes without cutting off the drive source (7-
segment LED display does not show “DSF”).)
* In the case of an optional (custom) specification, the
optional (custom) specification is given priority over the
deadman-switch enabling physical axes, drive-source cutoff
specification, servo OFF specification, 7-segment display
specification, etc.
10 (For
expansion)
0
11
Default acceleration
20
1 to 200
0.01 G
Used if not specified in position data, program or SIO
message, etc.
12
Default deceleration
20
1 to 200
0.01 G
Used if not specified in position data, program or SIO
message, etc.
13
Default speed
30
1 to 250
mm/s
Used if not specified in SIO message or position data, when
movement is to be continued, etc.
14
Valid selection when
operation point data
deceleration is 0
0
0 to 5
0: “Deceleration = Acceleration” when the deceleration in the
operation point data is “0”
1: “Deceleration = 0” when the deceleration in the operation
point data is “0”
15
Maximum jog speed
when home return is
incomplete
30
1 to 250
mm/s
16 to
19
(For expansion)
0
a
20 Maximum
operating
speed check timing
1
0 to 1
0: Check at input
1: Check at operation
* If “Check at operation” is selected, the distribution
speed (CP) of specified speed or the specified speed
(PTP) will be compared against the maximum operating
speed of each axis and clamped at the allowable speed.
Accordingly, the system can achieve its maximum
performance in accordance with the operation
command. However, complete check cannot be
performed at input (since the command/operation start
position is indeterminable). In the case of CP, the
distribution speed will vary depending on the operation
start position. Therefore, specifying CP at an
unspecified position (first point movement, etc.) will
cause the speed to fluctuate depending on where the
operation is started.
21 Maximum
operating
speed for input value
check
300
1 to 9999
mm/s
If “Input” is selected as the maximum speed check timing, this
parameter will be used to check for input error.
22
Maximum acceleration
100
1 to 999
0.01 G
23
Maximum deceleration
100
1 to 999
0.01 G
24 Minimum
emergency
deceleration
30
1 to 300
0.01 G
25 (Acceleration/deceleration
at home return (old))
30
1 to 300
0.01 G
(Invalid)
26 Acceleration/deceleration
specification type
0
0 to 5
0: T system, 1: P, M system
27
Master axis type
0
0 to 5
0: T system, 1: P system