Parameters common to all axes – IAI America TT-C3 User Manual

Page 307

background image

297

INTELLIGENT ACTUATOR

Appendix

Appendix

2. Parameters Common to All Axes

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

1

Effective axis pattern

0000B

00B to

11111111B

2

Default override

100

1 to 100

Used if not specified in program. (Invalid for SIO operation)

3 to 8 (For expansion)

0

9 Deadman-switch

enabling

physical axis pattern

11111111B 00B

to

11111111B

Not affected by a BASE command. (Always specify 11111111
if all axes are used. If not, the servo may be turned off only for
the specified axes without cutting off the drive source (7-
segment LED display does not show “DSF”).)
* In the case of an optional (custom) specification, the

optional (custom) specification is given priority over the
deadman-switch enabling physical axes, drive-source cutoff
specification, servo OFF specification, 7-segment display
specification, etc.

10 (For

expansion)

0

11

Default acceleration

20

1 to 200

0.01 G

Used if not specified in position data, program or SIO
message, etc.

12

Default deceleration

20

1 to 200

0.01 G

Used if not specified in position data, program or SIO
message, etc.

13

Default speed

30

1 to 250

mm/s

Used if not specified in SIO message or position data, when
movement is to be continued, etc.

14

Valid selection when
operation point data
deceleration is 0

0

0 to 5

0: “Deceleration = Acceleration” when the deceleration in the

operation point data is “0”

1: “Deceleration = 0” when the deceleration in the operation

point data is “0”

15

Maximum jog speed
when home return is
incomplete

30

1 to 250

mm/s

16 to

19

(For expansion)

0

a

20 Maximum

operating

speed check timing

1

0 to 1

0: Check at input
1: Check at operation

* If “Check at operation” is selected, the distribution

speed (CP) of specified speed or the specified speed
(PTP) will be compared against the maximum operating
speed of each axis and clamped at the allowable speed.
Accordingly, the system can achieve its maximum
performance in accordance with the operation
command. However, complete check cannot be
performed at input (since the command/operation start
position is indeterminable). In the case of CP, the
distribution speed will vary depending on the operation
start position. Therefore, specifying CP at an
unspecified position (first point movement, etc.) will
cause the speed to fluctuate depending on where the
operation is started.

21 Maximum

operating

speed for input value
check

300

1 to 9999

mm/s

If “Input” is selected as the maximum speed check timing, this
parameter will be used to check for input error.

22

Maximum acceleration

100

1 to 999

0.01 G

23

Maximum deceleration

100

1 to 999

0.01 G

24 Minimum

emergency

deceleration

30

1 to 300

0.01 G

25 (Acceleration/deceleration

at home return (old))

30

1 to 300

0.01 G

(Invalid)

26 Acceleration/deceleration

specification type

0

0 to 5

0: T system, 1: P, M system

27

Master axis type

0

0 to 5

0: T system, 1: P system