beautypg.com

IAI America TT-C3 User Manual

Page 106

background image

96

INTELLIGENT ACTUATOR

Chapter 4 Commands

2.

Explanation

of

Commands

1-6 Timer

z TIMW (Timer)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

TIMW

Time

Prohibited TU

[Function]

Stop the program and wait for the time specified in operand 1.
The setting range is 0.01 to 99, and the unit is second.
The output will turn ON when the specified time has elapsed and the program proceeds to
the next step.

[Example 1]

TIMW

1.5

Wait for 1.5 seconds.

[Example 2]

LET

1

10

Assign 10 to variable 1.

TIMW

*1

Wait for the content of variable 1 (10 seconds).

This manual is related to the following products: