INTELLIGENT ACTUATOR

Appendix

Appendix

7. Other

Parameters

No Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

1

Auto-start program number

0

0 to 64

(Invalid if “0” is set)

2

I/O processing program
number at operation/program
abort

0

0 to 64

The start trigger is determined from the “I/O processing
program start type at operation/program abort.” (Note: This
program will be started before confirming an abort of other
programs.)
(Invalid if “0” is set) * If the setting is valid, the number of
user program tasks that can be used will decrease by 1.
Other programs cannot be started from this program.

3

I/O processing program
number at all operation pause

0

0 to 64

This program will be started when an all-operation-pause
command is issued due to an all-operation-pause factor.
(Only when a program is running) (Invalid if “0” is set) * If
the setting is valid, the number of user program tasks that
can be used will decrease by 1.

4

Program abort type at error

0

0 to 5

0: Cancel only the program in which an error of operation-

cancellation level or higher has generated. (If the error
requires the drive source to be cut off, all programs
other than the “I/O processing program at
operation/program abort” will be cancelled.)

1: Cancel all programs other than the “I/O processing

program at operation/program abort” when an error of
operation-cancellation level or higher has generated.

5

I/O processing program start
type at operation/program
abort

0

0 to 5

0: When all-operation-cancellation factor has generated

(Only when a program is running)

1: When all-operation-cancellation factor has generated

(Always)

2: All-operation-cancellation factor + Error of operation-

cancellation level or higher (“Other parameter No. 4 = 0”
is considered) (Only when a program is running)

3: All-operation-cancellation factor + Error of operation-

cancellation level or higher (“Other parameter No. 4 = 0”
is considered) (Always)

6

PC/TP reconnection delay at
software reset

11000

1 to 99999

msec

* The setting will become effective after the controller, PC

software or TP is shut down and restarted.

7 to 8 (For expansion)

0

9 Deadman-switch

recovery

type

0

0 to 2

0: Abort operations/programs
2: Operation continued (Only during automatic operation. *

In the PC software version is 1.0.0.5 or later or TP
application version is 1.01 or later, operation
commands from the PC software/TP will be aborted on
the PC software/TP side.)

PC: PC software
TP: Teaching pendant