Other parameters – IAI America TT-C3 User Manual
Page 319
309
INTELLIGENT ACTUATOR
Appendix
Appendix
7. Other
Parameters
No Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
1
Auto-start program number
0
0 to 64
(Invalid if “0” is set)
2
I/O processing program
number at operation/program
abort
0
0 to 64
The start trigger is determined from the “I/O processing
program start type at operation/program abort.” (Note: This
program will be started before confirming an abort of other
programs.)
(Invalid if “0” is set) * If the setting is valid, the number of
user program tasks that can be used will decrease by 1.
Other programs cannot be started from this program.
3
I/O processing program
number at all operation pause
0
0 to 64
This program will be started when an all-operation-pause
command is issued due to an all-operation-pause factor.
(Only when a program is running) (Invalid if “0” is set) * If
the setting is valid, the number of user program tasks that
can be used will decrease by 1.
4
Program abort type at error
0
0 to 5
0: Cancel only the program in which an error of operation-
cancellation level or higher has generated. (If the error
requires the drive source to be cut off, all programs
other than the “I/O processing program at
operation/program abort” will be cancelled.)
1: Cancel all programs other than the “I/O processing
program at operation/program abort” when an error of
operation-cancellation level or higher has generated.
5
I/O processing program start
type at operation/program
abort
0
0 to 5
0: When all-operation-cancellation factor has generated
(Only when a program is running)
1: When all-operation-cancellation factor has generated
(Always)
2: All-operation-cancellation factor + Error of operation-
cancellation level or higher (“Other parameter No. 4 = 0”
is considered) (Only when a program is running)
3: All-operation-cancellation factor + Error of operation-
cancellation level or higher (“Other parameter No. 4 = 0”
is considered) (Always)
6
PC/TP reconnection delay at
software reset
11000
1 to 99999
msec
* The setting will become effective after the controller, PC
software or TP is shut down and restarted.
7 to 8 (For expansion)
0
9 Deadman-switch
recovery
type
0
0 to 2
0: Abort operations/programs
2: Operation continued (Only during automatic operation. *
In the PC software version is 1.0.0.5 or later or TP
application version is 1.01 or later, operation
commands from the PC software/TP will be aborted on
the PC software/TP side.)
PC: PC software
TP: Teaching pendant