30

INTELLIGENT ACTUATOR

Chapter 1 Installation

2.

Speci

¿

cations

(3) Assignment example of output function selection (area 2)

Output function selection 300 (area 2) (ALM), currently set by “Output function selection 300 (area
2),” can be assigned to the output port set by “Physical output port number for output function
selection 300 (area 2)” to output the applicable signal from this port. An example is given below.

Set the function of output function selection 300 (area 2) using I/O parameter No. 331, “Output
function selection 300 (area 2).” For details, refer to Appendix, “Parameter List.”
The physical output port number for output function selection 300 (area 2) (ALM) is set by I/O
parameter No. 315, “Physical output port number for output function selection 300 (area 2).”
If “316” is set in this parameter, for example, the function of output function selection 300 (area 2)
(ALM) is assigned to “output port No. 316.”
Accordingly, the signal of output function selection 300 (area 2) (ALM) is output to output port 316.
Note, however, that the above parameter will become invalid when “0 (default value: normally the
parameter is set to this value before shipment)” is set, in which case the signal will not be output.

Based on the above setting, the ALM signal can now be output to a different port (output port set
for area 2) without disabling the ALM LED on the front panel (without changing the setting of
“Physical input port number for output function selection 300” for output signal selection 300).

Note: Although ports of desired output numbers can be set separately, error No. 685, “I/O function

selection physical port number error” will generate if duplicate port numbers are set.