beautypg.com

I/o parameters, Appendix – IAI America TT-C3 User Manual

Page 294

background image

284

INTELLIGENT ACTUATOR

Appendix

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

37 Input

function

selection

007

1

0 to 5

0: General-purpose input
1: Program number specified for program start (least

significant bit)

* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

38 Input

function

selection

008

1

0 to 5

0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

39 Input

function

selection

009

1

0 to 5

0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

40 Input

function

selection

010

1

0 to 5

0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

41 Input

function

selection

011

1

0 to 5

0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

42 Input

function

selection

012

1

0 to 5

0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

43 Input

function

selection

013

1

0 to 5

0: General-purpose input
1: Program number specified for program start
2: Error reset (On edge)
* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

44 Input

function

selection

014

0

0 to 5

0: General-purpose input (Cancel cutoff when the drive-

source cutoff factor is removed)

1: Drive-source cutoff reset input (ON edge) (Valid when the

factor has been removed)

* The condition of output port No. 314 (internal DIO) is

input to input port No. 014 (internal DIO).

45 Input

function

selection

015

0

0 to 5

0: General-purpose input
1: Home return of all valid axes (ON edge) (Servo ON must

be executed first = I/O parameter No. 32, Axis-specific
parameter No. 13)

2: Home return of all valid incremental axes (ON edge)

(Main application version 0.16 or later) (Servo ON must
be executed first = I/O parameter No. 32, Axis-specific
parameter No. 13)

* The condition of output port No. 315 (internal DIO) is

input to input port No. 015 (internal DIO).

46 Output

function

selection 300

1

0 to 20

0: General-purpose output
1: Output error of operation-cancellation level or higher

(ON)

2: Output error of operation-cancellation level or higher

(OFF)

3: Output error of operation - cancellation level or higher +

emergency stop (ON)

4: Output error of operation - cancellation level or higher +

emergency stop (OFF)

* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

This manual is related to the following products: