I/o parameters, Appendix – IAI America TT-C3 User Manual
Page 294
284
INTELLIGENT ACTUATOR
Appendix
Appendix
I/O Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
37 Input
function
selection
007
1
0 to 5
0: General-purpose input
1: Program number specified for program start (least
significant bit)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
38 Input
function
selection
008
1
0 to 5
0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
39 Input
function
selection
009
1
0 to 5
0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
40 Input
function
selection
010
1
0 to 5
0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
41 Input
function
selection
011
1
0 to 5
0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
42 Input
function
selection
012
1
0 to 5
0: General-purpose input
1: Program number specified for program start
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
43 Input
function
selection
013
1
0 to 5
0: General-purpose input
1: Program number specified for program start
2: Error reset (On edge)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
44 Input
function
selection
014
0
0 to 5
0: General-purpose input (Cancel cutoff when the drive-
source cutoff factor is removed)
1: Drive-source cutoff reset input (ON edge) (Valid when the
factor has been removed)
* The condition of output port No. 314 (internal DIO) is
input to input port No. 014 (internal DIO).
45 Input
function
selection
015
0
0 to 5
0: General-purpose input
1: Home return of all valid axes (ON edge) (Servo ON must
be executed first = I/O parameter No. 32, Axis-specific
parameter No. 13)
2: Home return of all valid incremental axes (ON edge)
(Main application version 0.16 or later) (Servo ON must
be executed first = I/O parameter No. 32, Axis-specific
parameter No. 13)
* The condition of output port No. 315 (internal DIO) is
input to input port No. 015 (internal DIO).
46 Output
function
selection 300
1
0 to 20
0: General-purpose output
1: Output error of operation-cancellation level or higher
(ON)
2: Output error of operation-cancellation level or higher
(OFF)
3: Output error of operation - cancellation level or higher +
emergency stop (ON)
4: Output error of operation - cancellation level or higher +
emergency stop (OFF)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)