beautypg.com

IAI America TT-C3 User Manual

Page 224

background image

214

INTELLIGENT ACTUATOR

Chapter 4 Commands

2.

Explanation

of

Commands

z PDEC (Decrement palletizing position number by 1)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

PDEC

Palletizing

number

Prohibited CC

Decrement by 1 the palletizing position number for the palletizing number specified in operand 1.
If the decremented value is considered normal as a palletizing position calculated under the current palletizing
setting, the value will be updated. If not, the value will not be updated.
If the output field is specified, the output will turn ON when the value was successfully decremented, and turn
OFF if the decrement failed.

z PSET (Set palletizing position number directly)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

PSET

Palletizing

number

Data CC

Set the value specified in operand 2 as the palletizing position number for the palletizing number specified in
operand 1.
If the specified value is considered normal as a palletizing position calculated under the current palletizing
setting, the value will be set. If not, the value will not be set.
If the output field is specified, the output will turn ON when the palletizing position number was successfully
updated, and turn OFF if the update failed.

This manual is related to the following products: