z SCRV (Set sigmoid motion ratio)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

SCRV

Ratio

Prohibited CP

[Function] Set the ratio of sigmoid motion control of the actuator in the value specified in operand 1.

The ratio is set as an integer in a range from 0 to 50 (%).

a

b

X 100 (%)

If the ratio is not set using this command or 0% is set, a trapezoid motion will be
implemented.
A SCRV command can be used with the following commands: MOVP, MOVL, MVPI, MVLI,
JBWF, JBWN, JFWF, JFWN

[Example 1]

SCRV

30

Set the sigmoid motion ratio to 30%.