I/o parameters, Appendix – IAI America TT-C3 User Manual
Page 292

282
INTELLIGENT ACTUATOR
Appendix
Appendix
1. I/O
Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
1 I/O
port
assignment
type
0
Reference only
0: Fixed assignment
2
Input port start number
with fixed standard I/O1
assignments
000
-1 to 599
0 + (Multiple of 8) (Invalid if a negative value is set)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
3 Output
port
start
number with fixed
standard I/O1
assignments
300
-1 to 599
300 + (Multiple of 8) (Invalid if a negative value is set)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
4
Input port start number
with fixed expanded
I/O2 assignments
32
-1 to 599
0 + (Multiple of 8) (Invalid if a negative value is set)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
5 Output
port
start
number with fixed
expanded I/O2
assignments
316
-1 to 599
300 + (Multiple of 8) (Invalid if a negative value is set)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
6
Input port start number
with fixed expanded
I/O1 assignments
(Network I/F module)
-1
-1 to 599
0 + (Multiple of 8) (Invalid if a negative value is set)
7 Output
port
start
number with fixed
expanded I/O1
assignments (Network
I/F module)
-1
-1 to 599
300 + (Multiple of 8) (Invalid if a negative value is set)
8
For future expansion
-1
-1 to 599
9
For future expansion
-1
-1 to 599
10 Standard
I/O1
error
monitor
1
0 to 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power
source)
3: Monitor (Monitor only errors relating to 24-V I/O power
source)
* Some exceptions apply.
11
Expanded I/O2 error
monitor
1
0 to 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power
source)
3: Monitor (Monitor only errors relating to 24-V I/O power
source)
* Some exceptions apply.
12
Expanded I/O1 error
monitor (Network I/F
module)
1
0 to 5
0: Do not monitor
1: Monitor
* Some exceptions apply.
13
For future expansion
1
0 to 5
14
Number of ports using
network-I/F-module
remote input
0
0 to 240
Refer to the operation manual for each network I/F card
(CC-Link, DeviceNet, etc.).
15
Number of ports using
network-I/F-module
remote input
0
0 to 240
Refer to the operation manual for each network I/F card
(CC-Link, DeviceNet, etc.).
16
(For future expansion =
Change prohibited)
0
0 to 256
Multiple of 8
17
(For future expansion =
Change prohibited)
0
0 to 256
Multiple of 8
18 to
19
(For expansion)
0
20
Input filtering periods
2
1 to 9
msec
Input signal is recognized when the status is held for twice
the period set by this parameter.
21
Register input filtering
periods
2
1 to 9
msec
Input signal is recognized when the status is held for twice
the period set by this parameter.
22
For future expansion
2000
Reference only
msec