INTELLIGENT ACTUATOR
Chapter 4 Commands
2.
Explanation
of
Commands
1-21
Palletizing Calculation Command
z PTNG (Get palletizing position number)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PTNG
Palletizing
number
Variable
number
CP
Assign the palletizing position number for the palletizing number specified in operand 1 to the variable specified
in operand 2.
If the output field is specified, the output will turn ON after this command is executed.
z PINC (Increment palletizing position number by 1)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PINC
Palletizing
number
Prohibited CC
Increment by 1 the palletizing position number for the palletizing number specified in operand 1.
If the incremented value is considered normal as a palletizing position number calculated under the current
palletizing setting, the value will be updated. If not, the value will not be updated.
If the output field is specified, the output will turn ON when the value was successfully incremented, and turn
OFF if the increment failed.