(2) Output part
External Output Specifications (NPN Specification)
Item
Specification
Load voltage
24 VDC
Maximum load current
100 mA per point, 400 mA per 8 ports Note)
Leakage current
0.1 mA max. per point
TD62084 (or equivalent)
Isolation method
Photocoupler isolation
External devices
[1] Miniature relay
[2] Sequencer input unit
Note) 400 mA is the maximum total load current of every eight ports from output port No. 316.
[Output circuit]
Note: The parameters are normally set to the
above port numbers before shipment.
Caution
In the event that the load is short-circuited or current exceeding the maximum load current is input, the
overcurrent protection circuit will be actuated to cut off the circuit. However, give due consideration to
the circuit connection layout to prevent short-circuit or overcurrent.
Internal circuit
Pin No. 1
Surge absorber
Output
terminal Load
External power supply
24 VDC
r 10%
Port Nos. 316 to
331
Pin No. 34