Installation environment, noise measures and other, 1 installation environment – IAI America TT-C3 User Manual
Page 54
44
INTELLIGENT ACTUATOR
Chapter 1 Installation
3.
Installation
Environment,
Noise
Measures
and
Other
3. Installation Environment, Noise Measures and Other
As for the use environment, the products explained in this manual can be used in an environment of
pollution degree 2
*1
or equivalent.
*1 Pollution degree 2: An environment normally subject to non-conductive contaminants only, but
conductive contaminants may generate temporarily due to bedewing.
(EN60947-5-1)
3.1 Installation
Environment
(1) When installing and wiring the Tabletop Robot, do not block the ventilation holes provided for
cooling. (Insufficient ventilation will not only prevent the robot from functioning fully, but it may also
result in failure.)
(2) Prevent foreign matter from entering the Tabletop Robot through the ventilation holes. Since the
controller inside the robot is not designed as dustproof or waterproof (oilproof), avoid using the
robot in a dusty place or place subject to oil mist or splashed cutting fluid.
(3) Do not expose the Tabletop Robot to direct sunlight or radiant heat from a high heat source such
as a heat-treating furnace.
(4) Use the Tabletop Robot in a non-condensing environment free from corrosive or inflammable
gases.
(5) Use the Tabletop Robot in an environment where it will not receive external vibration or impact.
(6) Prevent electrical noise from entering the Tabletop Robot or its cables.