I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

56

Output function
selection 310

0

0 to 5

0: General-purpose output
* The condition of output port No. 310 (internal DIO) is

input to input port No. 003 (internal DIO).

(The parameters are normally set to the above port

numbers before shipment.)

57

Output function
selection 311

0

0 to 5

0:

General-purpose

output

* The condition of output port No. 311 (internal DIO) is

input to input port No. 004 (internal DIO).

(The parameters are normally set to the above port

numbers before shipment.)

58

Output function
selection 312

0

0 to 5

0:

General-purpose

output

* The condition of output port No. 312 (internal DIO) is

input to input port No. 005 (internal DIO).

(The parameters are normally set to the above port

numbers before shipment.)

59

Output function
selection 313

0

0 to 5

0:

General-purpose

output

* The condition of output port No. 313 (internal DIO) is

input to input port No. 006 (internal DIO).

(The parameters are normally set to the above port

numbers before shipment.)

60

Output function
selection 314

0

0 to 5

0:

General-purpose

output

* The condition of output port No. 314 (internal DIO) is

input to input port No. 014 (internal DIO).

(The parameters are normally set to the above port

numbers before shipment.)

61

Output function
selection 315

0

0 to 5

0:

General-purpose

output

* The condition of output port No. 315 (internal DIO) is

input to input port No. 015 (internal DIO).

(The parameters are normally set to the above port

numbers before shipment.)

62

Physical input port
number for axis-1 brake
forced release

0

0 to 299

Forcibly unlock the brake when the applicable port is ON (be
aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is specified)
* The synchro slave axis will follow the synchro master axis.

63

Physical input port
number for axis-2 brake
forced release

0

0 to 299

Forcibly unlock the brake when the applicable port is ON (be
aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is specified)
* The synchro slave axis will follow the synchro master axis.

64

Physical input port
number for axis-3 brake
forced release

0

0 to 299

Forcibly unlock the brake when the applicable port is ON (be
aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is specified)
* The synchro slave axis will follow the synchro master axis.

65

Physical input port
number for axis-4 brake
forced release

0

0 to 299

Forcibly unlock the brake when the applicable port is ON (be
aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is specified)
* The synchro slave axis will follow the synchro master axis.

66 to

69

(For expansion)

0

70

Unaffected general-
purpose output area
number (MIN) when all
operations/programs
are aborted

300

0 to 599

*

Important: Outputs in this area must be operated

under the responsibility of user programs including the “I/O
processing program at operation/program abort.” Outputs
outside this area will be forcibly turned OFF. (Invalid if “0” is
set)

71

Unaffected general-
purpose output area
number (MAX) when all
operations/programs
are aborted

315

0 to 599