18. Moving to a Specified Position Number

Description

Read an external BCD code input as a position number and cause the actuator to move to the
corresponding position.

Example of Use

Use an INB command to read a BCD code from an input port as a position number. Up to three digits
can be specified as a position number.

Input assignments

Output

Port

Description

303 Completion of movement

28 Start

input

16

Position specification 1

17

Position specification 2

18

Position specification 4

19

Position specification 8

20

Position specification 10

21

Position specification 20

22

Position specification 40

23

Position specification 80

24

Position specification 100

25

Position specification 200

26

Position specification 400

27

Position specification 800

Application program

Flowchart

Start

Initial setting

Start input

BDC is read

Movement

completion OFF

Move to the

specified position

number

Movement

completion ON