Moving to a specified position number – IAI America TT-C3 User Manual
Page 278
268
INTELLIGENT ACTUATOR
Appendix
Appendix
18. Moving to a Specified Position Number
Description
Read an external BCD code input as a position number and cause the actuator to move to the
corresponding position.
Example of Use
Use an INB command to read a BCD code from an input port as a position number. Up to three digits
can be specified as a position number.
Input assignments
Output
Port
Description
303 Completion of movement
28 Start
input
16
Position specification 1
17
Position specification 2
18
Position specification 4
19
Position specification 8
20
Position specification 10
21
Position specification 20
22
Position specification 40
23
Position specification 80
24
Position specification 100
25
Position specification 200
26
Position specification 400
27
Position specification 800
Application program
Flowchart
Start
Initial setting
Start input
BDC is read
Movement
completion OFF
Move to the
specified position
number
Movement
completion ON