I/o parameters – IAI America TT-C3 User Manual
Page 302
292
INTELLIGENT ACTUATOR
Appendix
Appendix
I/O Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
289
Physical input port
number for input
function selection 006
-1
-1 to 299
* Invalid if a negative value is set. (Input function selection
006 will be specified to input port No. 6.)
(Main application version 0.19 or later)
290
Physical input port
number for input
function selection 007
-1
-1 to 299
* Invalid if a negative value is set. (Input function selection
007 will be specified to input port No. 7.)
* If “start program number” is specified for input function
selection 007, specify the next larger input port number
immediately adjacent to the LSB side of the start program
number.
(Main application version 0.19 or later)
291
Physical input port
number for input
function selection 008
-1
-1 to 299
* Invalid if a negative value is set. (Input function selection
008 will be specified to input port No. 8.)
* If “start program number” is specified for input function
selection 008, specify the next larger input port number
immediately adjacent to the LSB side of the start program
number.
(Main application version 0.19 or later)
292
Physical input port
number for input
function selection 009
-1
-1 to 299
* Invalid if a negative value is set. (Input function selection
009 will be specified to input port No. 9.)
* If “start program number” is specified for input function
selection 009, specify the next larger input port number
immediately adjacent to the LSB side of the start program
number.
(Main application version 0.19 or later)
293
Physical input port
number for input
function selection 010
-1
-1 to 299
* Invalid if a negative value is set. (Input function selection
010 will be specified to input port No. 10.)
* If “start program number” is specified for input function
selection 010, specify the next larger input port number
immediately adjacent to the LSB side of the start program
number.
(Main application version 0.19 or later)
294
Physical input port
number for input
function selection 011
-1
-1 to 299
* Invalid if a negative value is set. (Input function selection
011 will be specified to input port No. 11.)
* If “start program number” is specified for input function
selection 011, specify the next larger input port number
immediately adjacent to the LSB side of the start program
number.
(Main application version 0.19 or later)
295
Physical input port
number for input
function selection 012
-1
-1 to 299
* Invalid if a negative value is set. (Input function selection
012 will be specified to input port No. 12.)
* If “start program number” is specified for input function
selection 012, specify the next larger input port number
immediately adjacent to the LSB side of the start program
number.
(Main application version 0.19 or later)