INTELLIGENT ACTUATOR

Appendix

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

327

Physical output port
number for output
function selection 312
(area 2)

0

0 to 599

* Invalid if “0” is set. (No output port will be specified for

output function selection 312 (area 2).)

(Main application version 0.19 or later)

328

Physical output port
number for output
function selection 313
(area 2)

0

0 to 599

* Invalid if “0” is set. (No output port will be specified for

output function selection 313 (area 2).)

(Main application version 0.19 or later)

329

Physical output port
number for output
function selection 314
(area 2)

0

0 to 599

* Invalid if “0” is set. (No output port will be specified for

output function selection 314 (area 2).)

(Main application version 0.19 or later)

330

Physical output port
number for output
function selection 315
(area 2)

0

0 to 599

* Invalid if “0” is set. (No output port will be specified for

output function selection 315 (area 2).)

(Main application version 0.19 or later)

331 Output

function

selection 300 (area 2)

0

0 to 20

0: General-purpose output
1: Error output of operation-cancellation level or higher (ON)
2: Error output of operation-cancellation level or higher

(OFF)

3: Error output of operation-cancellation level or higher +

Emergency stop output (ON)

4: Error output of operation-cancellation level or higher +

Emergency stop output (OFF)

(Main application version 0.19 or later)

332 Output

function

selection 301 (area 2)

0

0 to 20

0: General-purpose output
1: READY output (PIO trigger program operation permitted)
2: READY output (PIO trigger program operation permitted

AND error output of operation-cancellation level or higher
not present)

3: READY output (PIO trigger program operation permitted

AND error output of cold-start level or higher not present)

(Main application version 0.19 or later)

333 Output

function

selection 302 (area 2)

0

0 to 20

0: General-purpose output
1: Emergency stop output (ON)
2: Emergency stop output (OFF)

(Main application version 0.19 or later)

334 Output

function

selection 303 (area 2)

0

0 to 5

0: General-purpose output
1: AUTO mode output
2: Output during automatic operation (other parameter No.

12)

(Main application version 0.19 or later)

335 Output

function

selection 304 (area 2)

0

0 to 5

0: General-purpose output
1: Output if all valid axes are at their homes (= 0)
2: Output if all valid axes completed home return

(coordinates have been confirmed)

3: Output if all valid axes are at their home preset

coordinates

336 Output

function

selection 305 (area 2)

0

0 to 5

0: General-purpose output
2: Output when the axis 1 servo is ON (system monitor task

output)

3: Reserved by the system

(Main application version 0.19 or later)

337 Output

function

selection 306 (area 2)

0

0 to 5

0: General-purpose output
2: Output when the axis 2 servo is ON (system monitor task

output)

3: Reserved by the system

(Main application version 0.19 or later)

338 Output

function

selection 307 (area 2)

0

0 to 5

0: General-purpose output
2: Output when the axis 3 servo is ON (system monitor task

output)

3: Reserved by the system

(Main application version 0.19 or later)