2.
Speci

¿

cations

(2) Output part

External Output Specifications

Item

Specification

Load voltage

24 VDC

Maximum load current

100 mA per point, 400 mA per 8 ports Note)

Leakage current

0.1 mA max. per point

TD62784 (or equivalent)

Isolation method

Photocoupler isolation

External devices

[1] Miniature relay
[2] Sequencer input unit

Note) 400 mA is the maximum total load current of every eight ports from output port No. 300.

[Output circuit]

Note: The parameters are normally set to the

above port numbers before shipment.

Caution

In the event that the load is short-circuited or a current exceeding the maximum load current is input,
the overcurrent protection circuit will be actuated to cut off the circuit. However, give due consideration
to the circuit connection layout to prevent short-circuit or overcurrent.

Internal circuit

Pin No. 1

Surge absorber

Output terminal

Load

External power supply
24 VDC

10%

Port Nos. 316
to 331

Pin No. 34