Caution – IAI America TT-C3 User Manual
Page 45
35
INTELLIGENT ACTUATOR
Chapter 1 Installation
2.
Speci
¿
cations
(2) Output part
External Output Specifications
Item
Specification
Load voltage
24 VDC
Maximum load current
100 mA per point, 400 mA per 8 ports Note)
Leakage current
0.1 mA max. per point
TD62784 (or equivalent)
Isolation method
Photocoupler isolation
External devices
[1] Miniature relay
[2] Sequencer input unit
Note) 400 mA is the maximum total load current of every eight ports from output port No. 300.
[Output circuit]
Note: The parameters are normally set to the
above port numbers before shipment.
Caution
In the event that the load is short-circuited or a current exceeding the maximum load current is input,
the overcurrent protection circuit will be actuated to cut off the circuit. However, give due consideration
to the circuit connection layout to prevent short-circuit or overcurrent.
Internal circuit
Pin No. 1
Surge absorber
Output terminal
Load
External power supply
24 VDC
10%
Port Nos. 316
to 331
Pin No. 34