beautypg.com

I/o parameters – IAI America TT-C3 User Manual

Page 299

background image

289

INTELLIGENT ACTUATOR

Appendix

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

120

Network attribute 1

1

0H to

FFFFFFFFH

Bits 0 to 3:

CC-Link remote register area
H/L byte swap selection (0: Do not swap, 1:
Swap)
* The number of used ports and number of

occupied stations in I/O parameter Nos. 14
and 15 must match.

121

Network attribute 2

0

0H to

FFFFFFFFH

122

Network attribute 3

0

0H to

FFFFFFFFH

123

Network attribute 4

0

0H to

FFFFFFFFH

Bits 0 to 3:

Ethernet TCP/IP message communication
Selection whether to permit 0.0.0.0 (IP address
of connection destination can be ignored) as IP
address of connection destination on server
(0: Do not permit 1: Permit (not recommended))

* Note: Number of clients that can be connected

simultaneously to one server port channel = 1

124

Network attribute 5

0

0H to

FFFFFFFFH

Ethernet TCP/IP message communication attribute

Ethernet client/server type
(0: Not in use

1: Client (Automatic assignment of own port number)

(2: Client (Specification of own port number)

o This setting is not recommended because of

device limitations, such as an error generation
when the port is opened for approx. 10 minutes
after disablement of close response check due to a
power failure at the connection destination, etc.)

3: Server (Specification of own port number))

* Note: Number of clients that can be connected

simultaneously to one server port channel = 1

Bits 0 to 3:

IAI protocol B/TCP (MANU mode)

* PC software can be connected only in the case of a

client.

Bits 4 to 7:

IAI protocol B/TCP (AUTO mode)

* PC software can be connected only in the case of a

client.

Bits 8 to 11: Channel 31 opened to user
Bits 12 to 15: Channel 32 opened to user
Bits 16 to 19: Channel 33 opened to user
Bits 20 to 23: Channel 34 opened to user

* If the parameter settings for own port number, client/server

type, IP address of connection destination and port
number of connection destination do not match completely
between the IAI protocol B/TCP MANU and AUTO modes,
the connection will be cut off when the MANU/AUTO mode
is switched.

125

Network attribute 6

1E32H

0H to

FFFFFFFFH

Bits 0 to 7:

Module-initialization check timer setting when
Ethernet is used (100 msec)

Bits 8 to 15: Module-initialization check timer setting when

Ethernet is not used (100 msec)

Bits 16 to 23: Increment of “PC/TP reconnection delay at

software reset” when Ethernet is used (sec)

126

Network attribute 7

7D007D0H

0H to

FFFFFFFFH

Ethernet TCP/IP message communication attribute

Bits 0 to 15:

Min timeout value (msec)

Bits 16 to 31:

Mout timeout value (msec)

This manual is related to the following products: