I/o parameters – IAI America TT-C3 User Manual
Page 299

289
INTELLIGENT ACTUATOR
Appendix
Appendix
I/O Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
120
Network attribute 1
1
0H to
FFFFFFFFH
Bits 0 to 3:
CC-Link remote register area
H/L byte swap selection (0: Do not swap, 1:
Swap)
* The number of used ports and number of
occupied stations in I/O parameter Nos. 14
and 15 must match.
121
Network attribute 2
0
0H to
FFFFFFFFH
122
Network attribute 3
0
0H to
FFFFFFFFH
123
Network attribute 4
0
0H to
FFFFFFFFH
Bits 0 to 3:
Ethernet TCP/IP message communication
Selection whether to permit 0.0.0.0 (IP address
of connection destination can be ignored) as IP
address of connection destination on server
(0: Do not permit 1: Permit (not recommended))
* Note: Number of clients that can be connected
simultaneously to one server port channel = 1
124
Network attribute 5
0
0H to
FFFFFFFFH
Ethernet TCP/IP message communication attribute
Ethernet client/server type
(0: Not in use
1: Client (Automatic assignment of own port number)
(2: Client (Specification of own port number)
o This setting is not recommended because of
device limitations, such as an error generation
when the port is opened for approx. 10 minutes
after disablement of close response check due to a
power failure at the connection destination, etc.)
3: Server (Specification of own port number))
* Note: Number of clients that can be connected
simultaneously to one server port channel = 1
Bits 0 to 3:
IAI protocol B/TCP (MANU mode)
* PC software can be connected only in the case of a
client.
Bits 4 to 7:
IAI protocol B/TCP (AUTO mode)
* PC software can be connected only in the case of a
client.
Bits 8 to 11: Channel 31 opened to user
Bits 12 to 15: Channel 32 opened to user
Bits 16 to 19: Channel 33 opened to user
Bits 20 to 23: Channel 34 opened to user
* If the parameter settings for own port number, client/server
type, IP address of connection destination and port
number of connection destination do not match completely
between the IAI protocol B/TCP MANU and AUTO modes,
the connection will be cut off when the MANU/AUTO mode
is switched.
125
Network attribute 6
1E32H
0H to
FFFFFFFFH
Bits 0 to 7:
Module-initialization check timer setting when
Ethernet is used (100 msec)
Bits 8 to 15: Module-initialization check timer setting when
Ethernet is not used (100 msec)
Bits 16 to 23: Increment of “PC/TP reconnection delay at
software reset” when Ethernet is used (sec)
126
Network attribute 7
7D007D0H
0H to
FFFFFFFFH
Ethernet TCP/IP message communication attribute
Bits 0 to 15:
Min timeout value (msec)
Bits 16 to 31:
Mout timeout value (msec)