INTELLIGENT ACTUATOR
Chapter 4 Commands
2.
Explanation
of
Commands
z PPUT (Write position data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PPUT
Axis
number
Position
number
CP
[Function] Write the value in variable 199 to the axis number specified in operand 1 in the position data
specified in operand 2.
[Example 1]
LET
199
150
Assign 150 to variable 199.
PPUT
2
3
Write the content of variable 199 (150) to axis 2 at position 3.
[Example 2]
LET
199
150
Assign 150 to variable 199.
LET
1
2
Assign 2 to variable 1.
LET
2
3
Assign 3 to variable 2
PPUT
*1
*2
Write the content of variable 199 (150) to the content of
variable 1 (axis 2) at the content of variable 2 (position 3).