beautypg.com

Use examples of key parameters – IAI America TT-C3 User Manual

Page 325

background image

315

INTELLIGENT ACTUATOR

Appendix

Appendix

9.

Use Examples of Key Parameters

You can a

s

si

gn functio

ns i

n addition to those availabl

e unde

r the factory

setting

s or

c

hange the factory-set functions, by chan

ging the

param

eter

values.

Before changing a paramet

er, be sure to read the

correspondi

ng section in the Li

st of Paramet

ers.

Descripti

on Action

Parameter

setti

ng

Mani

pul

ation/operati

on

Want to prevent errors relating to the

standar

d I/O b

oard and field

net

w

o

rk

boar

d (Devic

eNet, CC-Link, etc.).

(Want to perform trial oper

ation

w

hen

w

iring is not

yet done, etc.)

I/O error monitor can be disabled to

prevent errors from occurring.

Set “0” in the I/O parameter

corresponding to the I/O board

w

h

os

e

error monit

or

you

w

a

nt to disable.

Standard

I/O

1: I/O

parameter No. 10

= 0

Expanded I/O2: I/O pa

ramete

r

No. 11

= 0

Field

net

w

o

rk: I

/O parameter No.

12 =

0

Set “0” in I/O p

a

rameter Nos. 10 and 11

to disable error

monitor for the standard

I/O board.

Note: T

o

operate a disabled I/O board,

be sure to rev

ert the parameter setting

to “1.”

Want to retain output status

w

h

ile

emergenc

y-stop signal

is input or the

safet

y

gate is open.

Minimum and

maximum port numbers

indic

ating the output ports

you

w

is

h

to

retain can be set.

I/O parameter No. 70 = Output port

number MIN

I/O parameter No. 71 = Output port

number MAX

Setting ex

am

ple) T

o

retain output ports

from port Nos. 316 through 331, set as

follo

w

s:

I/O parameter No. 70 = 316

I/O parameter No. 71 = 331

m

T

he status of output port Nos. 316

throug

h 33

1

w

ill be retai

ne

d

w

h

ile

emergenc

y-stop signal

is input or the

safet

y

gate is open.

Note:

T

he parameter

s are

normal

ly

s

e

t to the abov

e

output port numbers befor

e

shipment.

Want to start p

rograms

w

h

ile

emergenc

y-stop signal

is input or the

safet

y

gate is open.

Programs to be started are I/O

process

ing or c

a

lcul

atio

n pro

g

rams that

do not command actuat

or operation

(PIO processing progr

ams).

A PIO processing program to start can

be set. Set in the applic

able

param

eters a desired PIO processing

progr

am as

w

e

ll as minim

um and

maximum port numbers indicating the

output ports at w

h

ich the program

w

ill

be proc

essed.

Other paramet

er No. 2 = PIO

process

ing pr

o

g

ram num

ber

I/O parameter No. 70 = Output port

number MIN

I/O parameter No. 71 = Output port

number MAX

Setting ex

am

ple) T

o

start program No.

5 that involv

es

pr

ocess

ing at o

u

tput

port Nos. 316 t

h

rough 331, set as

follo

w

s:

Other paramet

er No. 2 = 5

I/O parameter No. 70 = 316

I/O parameter No. 71 = 331

m

Program No. 5

w

ill start

w

h

ile

emergenc

y-stop signal

is input or the

safet

y

gate is open. Output port Nos.

316 thro

ug

h 33

1 can be

used

for

process

ing.

Note:

T

he parameter

s are

normal

ly

s

e

t to the abov

e

output port numbers befor

e

shipment.

This manual is related to the following products: