IAI America TT-C3 User Manual
Page 143
133
INTELLIGENT ACTUATOR
Chapter 4 Commands
2.
Explanation
of
Commands
1-11
Actuator Control Declaration
z VEL (Set speed)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional VEL
Speed
Prohibited CP
[Function] Set the actuator travel speed in the value specified in operand 1.
The unit is mm/s.
The maximum speed will vary depending on the model of the actuator connected. Set a
speed not exceeding the applicable maximum speed.
(Note 1)
Decimal places cannot be used. An error will generate
(Note 2)
The minimum speed is 1 mm/s.
[Example 1]
VEL
100
Set the speed to 100 mm/s.
MOVP
1
Move to point 1 at 100 mm/s.
[Example 2]
VEL
200
Set the speed to 200 mm/s.
MOVP
2
Move to point 2 at 200 mm/s.
[Example 3]
LET
1
300
Assign 300 to variable 1.
VEL
*1
Set the speed to the content of variable 1 (300 mm/s).