beautypg.com

IAI America TT-C3 User Manual

Page 333

background image

323

INTELLIGENT ACTUATOR

Appendix

Appendix

(In the panel

wind

ow, the three di

gits after “E” in

dicate an error n

u

mber.)

Erro

r No.

Erro

r name

De

scription, a

c

tion, etc.

A44

Point-data

count specification error

The sp

ecified number of point data is invalid.

A45

Symbol-record count speci

fic

ation erro

r

The sp

ecifie

d

numbe

r of symbol records is invalid.

A46

Variabl

e-data count specification error

The specified number of variable data is

invalid.

A48

Erro

r-d

etail q

uery type 1 error

Error-detail query type 1 is invalid.

A49

Erro

r-d

etail q

uery type 2 error

Error-detail query type 2 is invalid.

A4A

Monitori

ng data type error

The data

type for monitoring data query is invalid.

A4B

Monitori

ng-re

cord co

unt sp

ecification error

The sp

ecified numbe

r of records for moni

toring data query is invalid.

A4C

Monitori

ng-operation

speci

al comm

and register busy erro

r

The drive

r sp

ecial

comm

a

nd ACK gen

e

rated a timeo

ut during

monitori

ng op

eration.

A4E

Parameter register busy error at

issuance of slave command

The driver

special

comm

and ACK generated a timeout at issuance o

f a

slave command.

A4F

Software

reset refusal error during operation

Software

reset (SIO) is prohibited during operation (program i

s

running,

servo i

s

in use, etc.).

A50

Drive-source

recovery request refusal error

The drive

-source

cutoff fact

or (error, dea

dman switch, safety gate,

emergency st

op, etc.) has

not been rem

oved.

A51

Operation-pause reset request ref

u

s

al error

The all-ope

ration-pause factor (drive-s

ource cutoff, operation-pause

signal, deadman switch,

safety gate, emergency

stop, etc.) has not

been removed.

A53

Refu

sal erro

r due to se

rvo ON

A processin

g not permitted

during servo

ON was attempted.

A54

Refu

sal erro

r due to un

sup

ported fun

ctio

n

The fun

ction is not su

pported.

A55

Refu

sal erro

r due to exclu

si

ve manufactu

rer fun

ction

A pr

ocessin

g not open

ed to

users othe

r than the man

u

facture

r was

attempted.

A56

Refusal error due to invalid data

The data is invalid.

A57

Program start

duplication error

An attempt was mad

e to st

art a pro

gra

m

currently run

ning.

A58

BCD error warning

The BCD value being

read may be invalid, or the value being

written

(variable 99) may be a neg

ative value, among other reasons.

A59

IN/OUT

com

mand po

rt flag error warni

ng

The num

ber of I/O ports (fl

ags) may hav

e exceeded 32, among other

reasons. Check the I/O

port (flag) specifi

cations.

A5B

C

h

ar

ac

ter-

s

tr

ing

o

value conversion e

rror wa

rni

ng

The sp

ecifie

d

numbe

r of co

nverting cha

racters i

s

invalid or characters

that cannot be converted to value are included.

A5C

Copying-character count

error warning with

SCPY command

The sp

ecifie

d

numbe

r of co

pying ch

ara

ct

ers i

s

invalid.

A5D

SCIF open e

rror in n

on-A

UTO mode

The ch

ann

el wa

s ope

ned i

n a non-A

UT

O mode. In the MANU mo

d

e, the

PC/TP connection must be forcibly

disconnected before openi

ng the

seri

al ch

ann

e

l opene

d to the use

r. Exerci

se caution.

A5E

I/O-port/flag count specifi

cation error

The sp

ecified number of I/O port

s/flags

is invalid.

A5F

Fieldbu

s e

rro

r (LERROR-ON

)

A LERRO

R-ON was d

ete

cted.

A60

Fieldbu

s e

rro

r (LERROR-BLINK)

A LERRO

R-B

LINK wa

s det

ected.

This manual is related to the following products: