2.
Explanation

of
Commands

z PAPR (Set push-motion approach distance, speed)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

PAPR

Distance

Speed CP

[Function] Set the operation to be performed when a PUSH command is executed.

Set the distance (push-motion approach distance) over which push-motion approach
operation (torque-limiting operation) will be performed in operand 1 (in mm), and set the
speed (push-motion approach speed) at which push-motion approach operation (torque-
limiting operation) will be performed in operand 2 (in mm/sec).
The push-motion approach distance specified in operand 1 may contain up to three decimal
places, while the speed specified in operand 2 cannot contain any decimal place.

[Example]

PAPR

100

30

Set the push-motion approach distance in a PUSH
command to 100 mm and the push-motion approach speed
to 30 mm/sec.

(Note)

The push-motion approach speed in an OVRD command will be clamped by the minimum speed
of 1 mm/sec. (Correct push-motion operation is not guaranteed at the minimum speed. Operation
at slow push-motion approach must be checked on the actual machine by considering the effects
of mechanical characteristics, etc.)

Y-axis

Position origin

Push-motion approach distance

Target position

X-axis

Start position of push-motion approach operation (torque-
limiting operation)