Other parameters – IAI America TT-C3 User Manual
Page 322

312
INTELLIGENT ACTUATOR
Appendix
Appendix
Other Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
38
PC/TP data protect 
setting (Symbol, 
parameter) 
0H
0H to
FFFFFFFFH
Bits 0 to 3:
Protect type (Parameter) (0: Read/write, 1: 
Read only, 2: No read/write) 
Bits 4 to 7:
Protect release method (Parameter) (0: Special 
operation)
Bits 8 to 11:
Protect type (Symbol) (0: Read/write, 1: Read 
only, 2: No read/write) 
Bits 12 to 15:
Protect release method (Symbol) (0: Special 
operation)
* Referenced by the PC/TP (PC software version 2.0.0.42 or
later and TP application version 1.09 or later)
39
(For future expansion)
0H
0H to
FFFFFFFFH
40 EEPROM
information
check type
3H
Reference only
For adjustment by the manufacture
41 Hardware
information
check type
E0H
Reference only
For adjustment by the manufacture
42
Hardware test type
7H
Reference only
For adjustment by the manufacture
43
Special monitor type
0H
0H to
FFFFFFFFH
Change strictly prohibited unless specified by the manufacturer.
44 (For
expansion)
0
45
Special start condition 
setting
0
0H to
FFFFFFFFH
Bits 0 to 3:
Enable start from PC/TP in AUTO mode = Used exclusively 
by the manufacturer (0: Do not enable, 1: Enable) 
Bits 4 to 7:
PIO program start (Input port 000) 
Single start selection (0: Normal, 1: Single start) 
* When single start is selected, the next PIO program start
(input port 000) will not be accepted as long as a program 
with the same program number as the one started by the 
last PIO program start (input port 000) is running. 
Bits 8 to 11:
Permission of auto program start when all-operation-
cancellation factor is present 
(0: Do not permit, 1: Permit) 
Bits 12 to 15:
Permission of ON edge acceptance for PIO program start 
(input port 000) when all-operation-cancellation factor is 
present
(0: Do not permit, 1: Permit) 
* This parameter specifies an ON-edge acceptance
condition. If the starting condition is not satisfied, an “Error 
No. A1E: Start condition non-satisfaction error” will 
generate.
PC: PC software 
TP: Teaching pendant 