INTELLIGENT ACTUATOR

Appendix

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

47 Output

function

selection 301

1

0 to 20

0: General-purpose output
1: READY output (PIO trigger program can be run)
2: READY output (PIO trigger program operation permitted

AND error of operation-cancellation level or higher not
present)

3: READY output (PIO trigger program operation permitted

AND error of cold-start level or higher not present)

* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

48 Output

function

selection 302

1

0 to 20

0: General-purpose output
1: Emergency-stop output (ON)
2: Emergency-stop output (OFF)
* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

49 Output

function

selection 303

2

0 to 5

0: General-purpose output
1: AUTO mode output
2: Output during automatic operation (Other parameter No.

12)

* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

50

Output function
selection 304

2

0 to 5

0: General-purpose output
1: Output if all valid axes are at their homes (= 0)
2: Output if all valid axes completed home return

(coordinates have been confirmed).

3: Output if all valid axes are at their home preset

coordinates

* Keep the default value if the main application version is

0.18 or earlier.

(Change prohibited)

51

Output function
selection 305

0

0 to 5

0: General-purpose output
1: For future expansion
2: Output when axis-1 servo is ON (System monitor task

output)

3: For future expansion

52

Output function
selection 306

0

0 to 5

0: General-purpose output
1: For future expansion
2: Output when axis-2 servo is ON (System monitor task

output)

3: For future expansion

53

Output function
selection 307

0

0 to 5

0: General-purpose output
1: For future expansion
2: Output when axis-3 servo is ON (System monitor task

output)

3: For future expansion

54

Output function
selection 308

0

0 to 5

0: General-purpose output
* The condition of output port No. 308 (internal DIO) is

input to input port No. 001 (internal DIO).

(The parameters are normally set to the above port

numbers before shipment.)

55

Output function
selection 309

0

0 to 5

0: General-purpose output
* The condition of output port No. 309 (internal DIO) is

input to input port No. 002 (internal DIO).

(The parameters are normally set to the above port

numbers before shipment.)