6 amp-defined t-, s-, and b-code macro call – Rockwell Automation 8520-GUM 9/Series CNC Grinder Operation and Programming Manual Documentation Set User Manual
Page 700

Paramacros
Chapter 20
20-56
Important: Your system installer can optionally disable the use of
AMP-defined G and M-code macro calls when in MDI mode. See your
system installer’s documentation to determine if this feature is functional
in MDI.
Important: Certain AMP-defined M-code macro calls cannot be called by
other AMP-defined macro calls (see page 20-57 for details).
Use this format when calling an AMP-defined T-, S-, or B-code macro:
T t ;
S s ;
or
B b ;
Where:
Is:
t:
is equal to the value assigned to parameter #149
s
is equal to the value assigned to parameter #147
b
is equal to the value assigned to parameter #146
Important: Programming arguments are not allowed with the
AMP-defined T-, S-, or B-code macro calls.
These macros are executed only as non-modal macro.
The execution of the T-, S-, or B-code macro calls is the same as M-code
macro calls with these exceptions:
the parameter # referenced when called
the macro program called
T calls macro 9000
S calls macro 9029
B calls macro 9028
In order for the T, S, or B words to call up a macro program, these
prerequisites must be met:
The value following the word must be equal to the value stored for the
specified parameter #.
For example:
T14;
The value of 14 must have been previously stored as the value for the
parameter #149.
20.6.6
AMP-Defined T-, S-, and
B-Code Macro Call