beautypg.com

HP Integrity NonStop H-Series User Manual

Page 356

background image

Simplified Installation and Management of Multiple
Identical NonStop Servers (Cloning)

DSM/SCM User’s Guide — 529846-014

19 - 7

Creating a Noncloning Configuration on a Master or

Clone

Creating a Noncloning Configuration on a
Master or Clone

It is unusual to update the configuration of a single member of a clone group. But if
needed, you can update the software configuration for an individual master or clone
system.

To create a software configuration to apply to a master but no other clone group
members:

1. Remove the master from the clone group. See

Removing a Master From a Clone

Group

on page 19-8.

2. Perform a normal Build/Apply on the master.

3. Make the system a master for the clone group again. See

Task 1: Define a Master

Target

on page 19-2.

To create a software configuration to apply to a single clone but no other clone group
members:

1. Remove the clone from the clone group. See

Removing a Master From a Clone

Group

on page 19-8.

2. In the Planner Interface, copy the current configuration to the clone, to ensure an

accurate starting point for this Build/Apply.

3. Perform a normal Build/Apply on the clone.

4. Make the system a clone in the clone group again. See

Task 1: Define a Master

Target

on page 19-2.

Note. Once you return it to the clone group, the system where you applied a unique
configuration will not have the same configuration as other clone group members.