Troubleshooting

DSM/SCM User’s Guide — 529846-014

13 - 15

Build/Apply Troubleshooting

During a Build, an Object Manager
error communicating with SWID
occurs.

The specified CONFTEXT file has either
been deleted, renamed, or secured so that
DSM/SCM cannot read it.

When a Build/Apply dialog box is opened,
DSM/SCM runs SWID to determine
whether the CONFTEXT file has changed
and a system generation is therefore
required.

This error might also indicate a SWID error
such as unresolved externals.

During a Build request, a message
indicates that the release is not
supported, or that the RVU is not
supported.

The software revision was not based
initially on an RVU.

Create a new revision, then do one of:

Select an RVU to copy to the configuration
revision.

Select the T6032 product for the site ID to
copy. The Planner Interface shows the RVU
selected.

The RVU of a configuration revision is
needed in order to choose the correct tools
for building the configuration (the correct
system generation program and correct
version of tools a system generation
program runs). This release level is
obtained when an RVU is selected from the
Software in Archive window and a Copy to
a revision is performed. This RVU is not
changed if you select List Products on
Software in Archive
inputs and then select
products to copy to the new revision.

This manual is related to the following products: