Check if additional disk space is required, Check that the spooler is active, Collect the information needed for the build – HP Integrity NonStop H-Series User Manual

Page 182: Determine the required sysnn subvolume

background image

Building and Applying a New Configuration

DSM/SCM User’s Guide — 529846-014

9 - 5

1. Check If Additional Disk Space Is Required

1. Check If Additional Disk Space Is Required

Before performing a Build/Apply, check the amount of additional disk space you might
need on the volume for new and changed files. For example, if your past configurations
normally take about 1500 megabytes of disk space and your new configuration has few
changes, you might need only 20 megabytes of additional free disk space (total disk
space of 1520 megabytes) to process that Apply.

2. Check That the Spooler Is Active

Check that the spooler is active if you are installing a SUT.

3. Collect the Information Needed for the Build

During the Build request, you must provide DSM/SCM with the information needed to
build the configuration revision and activate the software:

The new SYSnn if required

Planner instructions to the operator at the target system

Defaults are provided for all scheduling, output and TSV locations, system
generation, and file placement options. However, you can specify different values
for these options as needed for this Build/Apply. You cannot change the TDL
locations of OSS files.

Determine the Required SYSnn Subvolume

If system generation is required, you must specify a SYSnn subvolume that is not
currently running (active). Otherwise, you can specify the current SYSnn. subvolume.

System Generation Is Required

If DSM/SCM indicates that system generation is required, you must specify a different
SYSnn than the current SYSnn. Specify a subvolume that is not in use (not on the list)
and use it when you apply the new configuration.

System Generation Is Not Required

You can specify either the same SYSnn or a different SYSnn. However, specifying a
different SYSnn subvolume when system generation is not required might require a
system load that would otherwise be unnecessary.

Caution. Selecting the same SYSnn when system generation is required will cause the Apply
to stop with errors. To load your system from the same SYSnn, enter a different SYSnn and
then change the SYSnn name after the Apply. See

Renaming the Managed SYSnn (Optional)

on page 12-2.