Page 142: Register: 0x0d (0x8d)
5-26
SCSI Operating Registers
Register: 0x0D (0x8D)
SCSI Status Zero (SSTAT0)
Read Only
ILF
SIDL Least Significant Byte Full
7
This bit is set when the least significant byte in the
register contains data. Data is
transferred from the SCSI bus to the
register before being sent to the DMA FIFO
and then to the host bus. The
register contains SCSI data received
asynchronously. Synchronous data received does not
flow through this register.
ORF
SODR Least Significant Byte Full
6
This bit is set when the least significant byte in the SCSI
Output Data Register (SODR, a hidden buffer register
which is not accessible) contains data. The SODR
register is used by the SCSI logic as a second storage
register when sending data synchronously. It is not
readable or writable by the user. It is possible to use this
bit to determine how many bytes reside in the chip when
an error occurs.
OLF
SODL Least Significant Byte Full
5
This bit is set when the least significant byte in the
contains data. The
register is the interface between
the DMA logic and the SCSI bus. In synchronous mode,
data is transferred from the host bus to the
register, and then to the SCSI Output
Data Register (SODR, a hidden buffer register which is
not accessible) before being sent to the SCSI bus. In
asynchronous mode, data is transferred from the host
bus to the
register, and
then to the SCSI bus. The SODR buffer register is not
used for asynchronous transfers. It is possible to use this
bit to determine how many bytes reside in the chip when
an error occurs.
7
6
5
4
3
2
1
0
ILF
ORF
OLF
AIP
LOA
WOA
RST
SDP0/
0
0
0
0
0
0
0
0