L-force | plc designer – Lenze PLC Designer PLC Designer (R2-x) User Manual
Page 750
L-force | PLC Designer
PLC Designer Visualization
748
DMS 3.2 EN 02/2011 TD29
Define what you want to get displayed in the alarm table:
Change alarm group: Press this button to get the selection tree of the alarm
configuration, which offers all alarm groups currently defined. Choose the desired
group (which even may contain just one alarm).
Note!
The name of the alarm group, as it is displayed here (e.g. "System/Alarmgroup1")
can be used as PREFIX in a XML-file for dynamic texts in order to get dynamic
language switching for the message texts in the alarm table; the associated ID in
this must be the number of that line in the Alarm group configuration table, that
defines the respective message text.
Priority: Define the priority for which you want to get displayed all alarms. Permissible
range: 0 to 255.
Alarm classes: Mark a class which you want to get displayed and press button Add to
add the class to the list in the window 'Alarm classes'. Do this for all required classes.
In order to remove a marked entry from the alarm classes window press button
Delete.
Activate options Column heading resp. Row heading, if the headings should be
displayed in the alarm table.