Compiler Errors and Warnings
DMS 3.2 EN 02/2011 TD29
577
1970
"Parameter manager: List '
imported!"
Check the Import-file *.prm for entries which do not match the current configuration
(standard values resp. XML-description file) of the Parameter Manager.
1980
Global network variables '
result in loss of data!"
In the configuration of the network variables list (Select list in the Resources tab and
open dialog 'Global variables list' via command 'Properties' in the context menu)
options 'Read' and 'Write' are activated. Regard that this might result in data losses
during communication.
1990
"No 'VAR_CONFIG' for '
For this variable there is no address configuration available in the
Variable_Configuration (VAR_CONFIG). Open window Variable_Configuration in the
Resources tab and there insert the appropriate configuration (Command 'Insert 'All
instance paths').
2500
"Task '
In the Task configuration a cyclic task has been created, for which no cycle time has
been defined. Enter an appropriate time span in dialog 'Taskattributes' at "Interval".
4710
"'
Check the configuration of the slider element in category 'Variables': There must be
defined a valid value for each of the fields 'Min.Value', 'Slider' and 'Max. Value'.
4711
"'
SysLibTargetVisu."
Install and use the current version of the library SysLibTargetVisu.library.