Compiler Errors and Warnings
DMS 3.2 EN 02/2011 TD29
623
4364
"A transition must be a boolean expression"
The result of the transition expression must be of type BOOL.
4365
"Time Constant expected after qualifier '
Open dialog ‚step attributes’ for the step '
time constant.
4366
"The label of the parallel branch is no valid identifier: '
Enter a valid identifier next to the triangle which marks the jump label.
4367
"The label '
There is already a jump label or a step with this name. Please rename correspondingly.
4368
"Action '
The action '
4369
"Exactly one network requried for a transition"
There are used several FBD resp. LD networks for a transition. Please reduce to 1
network.
4370
"Additional lines found after correct IL-transition"
Remove the not needed lines at the end of the transition.
4371
"Invalid characters following valid expression: '
Remove the not needed characters at the end of the transition.