Error number
Meaning
507
Incorrect format specification during a write access
531
Incorrect format specification during the assignment
532
Code contains float/double parameters (e. g. supply voltage C00205 or
voltage of rechargeable battery C00207); this format is not supported by
the POU.
further
Internal software error; please address the Lenze service.
2.2.2
The function LLS_AddLog - generate a logbook
Function library: PlcLoggingAccess.lib
This function renders it possible to make an entry in the logbook of the industrial PC.
The function supplies a return value TRUE if the entry was carried out.
Inputs
Identifier/data type
Information/possible settings
eSeverity
LLS_TSeverity
Logging Severity - risk of the error
• LLS_FatalError
• LLS_Error, LLS_Warning
• LLS_Information
The Enum parameter eSeverity (IEC_INT) transferred to Add2Log as
severity (BYTE).
eFacility
LLS_TFacility
Logging Facility: - area from which the error is reported
• LLS_PLC_USER_LOG_SCOPE1
• LLS_PLC_USER_LOG_SCOPE2
• LLS_PLC_USER_LOG_SCOPE3
The Enum parameter eFacility (IEC_INT) is transferred to Add2Log as
Facility (WORD).
sLogPayLoad
STRING(80)
Logbook entry
The Ansi string from "sLogPayLoad" is transferred to Add2Log as 1-byte
string parameter. ("hs", SLOGPAYLOAD)