The Resources
360
DMS 3.2 EN 02/2011 TD29
If a DP master is selected in the configuration tree, the following dialogs will be
available in the right part of the configuration: Base parameters, DP Parameter, Bus
parameters, Module parameters.
DP master configuration dialog
If a DP slave is selected, which is inserted below a DP master, the following dialogs can
be available (depending on the definitions in the configuration file): Base parameters,
DP parameters, Input/Output, User parameters, Groups, Module parameters.
Depending on the settings in the configuration file the dialog "DP Parameters" might
have another title .
DP slave configuration dialog
If a DP slave is inserted on the level of a master, the following dialogs are available for
configuration: Base parameters, DP parameters, Input/Output, Module parameters.
Base parameters of the DP master
The Base parameters dialog of a DP master matches that of the other modules (see
'Base parameters of an I/O Module').
Module parameters of the DP master
The Module parameters dialog of a DP master matches that of the other modules: The
parameters assigned to the master in addition to the DP and bus parameters in the
configuration file are displayed here and the values can be edited in the standard case
(see 'Module parameters of an I/O Module' ).