Compiler Errors and Warnings
634
DMS 3.2 EN 02/2011 TD29
4623
The project gains write access to the same memory area at more than one place. See
the description of command 'Project' 'Check' 'Multiple write access to output'.
4650
"AxisGroup '
In the PLC Configuration in the definition of the axis group (dialog 'Module
parameters', column 'Value') there is a name defined for the task which is controlling
the data transfer of this axis group, which is not known in the Task Configuration.
Correct Task Configuration resp. PLC Configuration correspondingly.
4651
"AxisGroup '
In dialog 'Module parameters' of the axis group enter a value for the cycle time
(dwCycle).
4652
"Drive '
In the PLC Configuration within the same axis group there is already a drive with the
same Drive ID. Select the drive in the configuration tree and define an ID in
configuration dialog 'Drive' which is unique within the axisgroup.
4656
"Drive '
Open the PLC Configuration and check the Scale entries in the configuration dialog of
the drive. All fields must have entries not equal "0".
4670
"CNC program '
In the CNC program a global variable is used (e.g. $glob_var$), which is not defined in
the project. Add the appropriate declaration resp. correct the assignment to the
variable in the CNC program.
4671
"CNC program '
There is a variable assigned in a instruction of the CNC program , which is declared of
a data type which is not valid in this place. Use another variable resp. correct the type
specification.