L-force | plc designer – Lenze PLC Designer PLC Designer (R2-x) User Manual
Page 596

L-force | PLC Designer
Compiler Errors and Warnings
594
DMS 3.2 EN 02/2011 TD29
3571
"The library 'SysLibCallback' is not included in the project! System events can not be
generated."
In order to create event tasks, the SysLibCallback.lib is needed. Link this library to the
project in the library manager or modify the task configuration (task attributs) in that
way that there is no task triggered by an event.
3572
"Watchdog interval of task '
'
In the task configuration in dialog 'Taskattributes' there is a watchdog time defined in
microseconds, which is out of the valid range defined in the XML-description file.
3573
"Watchdog interval of task '
In the task configuration in dialog 'Taskattributes' there is a watchdog time defined in
percents, which is out of the valid range defined in the XML-description file.
3574
"The event variable '
times as an event"
A Singleton event is used several times in the task configuration. For information on
singleton events see the description in 'Insert' 'Insert task' or 'Insert' 'Append Task'.
3575
"Task '
Correct the cycle time accordingly in the Taskattributes dialog for this task. The target
system defines a base time and prescribes that the cycle time must be equal to or be a
multiple of this base time.
3600
"Implicit variables not found!"
Use command ‚Rebuild all’. If nevertheless you get the error message again please
contact the PLC manufacturer.