Compiler Errors and Warnings
574
DMS 3.2 EN 02/2011 TD29
1600
"Open DB unclear (generated code may be erroneous)."
The original Siemens program does not tell, which POU is openend.
1700
"Input not connected."
An input box is used in CFC which has no assignment. For this no code will be
generated.
1750
"Step '
Open dialog 'Step attributes' for this step and correct the time definitions.
1751
"Caution with usage of variable '
influences the behaviour of the step sequence."
We recommend to rename the variable, so that unique identifiers are used within the
project and undesired side effects can be avoided.
1800
"
The visualization element contains an expression which cannot be monitored. Check
variable name and placeholder replacements.
1801
"'
In the configuration of the visualization object at field input a composed expression is
used. Replace this by a single variable.
1802
"
Make sure, that an external bitmap-file is available in that path which is defined in
the visualization configuration dialog.