beautypg.com

Allied Telesis AT-DC2552XS User Manual

Page 207

background image

AT-DC2552SX Switch Command Line Interface User’s Guide

Section I: Switch Management

207

notifyview

Specifies the name of an existing SNMPv3 view that defines the
MIB objects the group members receive as notifications. If you omit
this parameter, the members cannot receive notification of any MIB
objects. The name is case-sensitive. You define SNMPv3 views
with the SNMP-SERVER VIEW command.

Mode

Global Configuration Mode

Description

Use this command to create an SNMPv3 group. Before you create a
group, you must define the group members, who are also known as users,
as well as the permitted views of MIB objects for this group.

You define users, including their security levels, with the SNMP-SERVER
USER command. See “SNMP-SERVER USER” on page 211. To define
whether or not a user can view, change, or receive notification of MIB
objects, use the SNMP-SERVER VIEW command. See “SNMP-SERVER
VIEW” on page 213.

Examples

This example creates a group called “admins.” The members of this group

must have a security level of authentication with encryption and can read
and change MIB objects named “most”:

awplus> enable
awplus# configure terminal
awplus(config)# snmp-server group admins priv read most
write most

This example creates a group called “operators.” The members of this

group must have a security level of authentication without encryption and
can read MIB objects named “standard”:

awplus> enable
awplus# configure terminal
awplus(config)# snmp-server group operators

auth read

standard