Melsec-q, 5 data used for positioning control, Remark – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 93: Checking the positioning parameters, Pr.1 to

5 - 5
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Control
Major positioning control
Manual control
Position control
Other control
Positioning parameter
OP
R co
nt
ro
l
1
-ax
is
l
in
ear
con
tr
o
l
2/
3/
4-
a
x
is
l
ine
a
r i
n
te
rp
ol
a
ti
o
n
co
nt
ro
l
1
-ax
is
f
ix
ed-
fe
ed
c
o
n
tr
o
l
2/
3/
4-
a
x
is
fi
xe
d
-f
e
e
d
co
nt
rol
2-
a
x
is
ci
rc
ul
ar
i
n
te
rpol
ati
o
n c
o
nt
rol
1
to
4 a
x
is
s
p
ee
d co
nt
ro
l
S
p
eed
-p
os
it
io
n
o
r po
s
it
ion
-s
pee
d
co
nt
ro
l
C
u
rre
nt
va
lu
e ch
ang
in
g
JU
M
P
i
n
st
ru
cti
o
n,
NOP
in
st
ru
cti
o
n
,
LO
OP
to
LE
N
D
Ma
n
ual
p
u
ls
e g
e
n
e
ra
to
r op
er
at
io
n
J
O
G ope
ra
ti
on
In
ch
in
g op
era
ti
o
n
R
e
la
te
d
s
u
b
f
unc
ti
on
Pr.25
Acceleration time 1
–
–
–
Pr.26
Acceleration time 2
–
–
–
Pr.27
Acceleration time 3
–
–
–
Pr.28
Deceleration time 1
–
–
–
Pr.29
Deceleration time 2
–
–
–
Pr.30
Deceleration time 3
–
–
–
12.7.7
Pr.31
JOG speed limit value
–
–
–
–
–
–
–
–
–
12.4.1
Pr.32
JOG operation acceleration time selection
–
–
–
–
–
–
–
–
–
–
Pr.33
JOG operation deceleration time selection
–
–
–
–
–
–
–
–
–
–
Pr.34
Acceleration/deceleration process
selection
–
–
–
Pr.35
S-pattern proportion
–
–
–
Pr.36
Sudden stop deceleration time
–
–
–
12.7.7
Pr.37
Stop group 1 sudden stop selection
–
–
–
–
Pr.38
Stop group 2 sudden stop selection
–
–
–
–
Pr.39
Stop group 3 sudden stop selection
–
–
–
–
Pr.40
Positioning complete signal output time
–
–
–
–
–
Pr.41
Allowable circular interpolation error width
–
–
–
–
–
–
–
–
–
–
D
e
ta
iled
p
a
ram
et
ers
2
Pr.42
External command function selection
–
–
12.5.1
12.7.2
:
Always set
:
Set as required ("–" when not set)
– :
Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or within the setting range, there is no
problem.)
Checking the positioning parameters
Pr.1 to
Pr.42
are checked with the following timing.
(1) When the "PLC READY signal [Y0]" output from the PLC CPU to the QD75
changes from OFF to ON
(2) When the test operation button is turned ON in the test mode using GX
Configurator-QP
(3) When an error check is carried out with GX Configurator-QP
REMARK
•
"High-level positioning control" is carried out in combination with the "major
positioning control".
Refer to the "major positioning control" parameter settings for details on the
parameters required for "high-level positioning control".