2 block start (normal start), Melsec-q, 2) positioning data setting example – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 422: Remark
10 - 8
MELSEC-Q
10 HIGH-LEVEL POSITIONING CONTROL
10.3.2 Block start (normal start)
In a "block start (normal start)", the positioning data groups of a block are continuously
executed in a set sequence starting from the positioning data set in "
Da.12
Start data
No." by one start.
Section [2] shows a control example where the " block start data" and "positioning
data" are set as shown in section [1].
[1] Setting examples
(1) Block start data setting example
Axis 1 block
start data
Da.11
Shape
Da.12
Start data No.
Da.13
Special start
instruction
Da.14
Parameter
1st point
1: Continue
1
0: Block start
–
2nd point
1: Continue
2
0: Block start
–
3rd point
1: Continue
5
0: Block start
–
4th point
1: Continue
10
0: Block start
–
5th point
0: End
15
0: Block start
–
•
•
(2) Positioning data setting example
Axis 1 position-
ing data No.
Da.1
Operation pattern
1
00: Positioning complete
2
11: Continuous path control
3
01: Continuous positioning control
4
00: Positioning complete
5
11: Continuous path control
6
00: Positioning complete
1 block
1 block
•
10
00: Positioning complete
•
15
00: Positioning complete
•
REMARK
Block :
"1 block" is defined as all the data continuing from the positioning data in which
"continuous positioning control" or "continuous path control" is set in the operation
pattern ( Da.1 ) to the positioning data in which "independent positioning control
(Positioning complete)" is set.