Melsec-q, 5 data used for positioning control, Pr.40 – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 130: Positioning complete signal output time
5 - 42
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting value, setting range
Setting value buffer memory
address
Item
Value set with peripheral device
Value set with sequence
program
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
Pr.40
Positioning complete signal
output time
0 to 65535 (ms)
0 to 65535 (ms)
0 to 32767 :
Set as a decimal
32768 to 65535:
Convert into hexadecimal
and set
300
59
209
359
509
Pr.41
Allowable circular
interpolation error width
The setting value range differs depending on the "
Pr.1
Unit
setting".
Here, the value within the [Table 1] range is set.
[Table 1] on right page
100
60
61
210
211
360
361
510
511
0: External positioning start
0
1: External speed change
request
1
2: Speed-position, position-
speed switching request
2
Pr.42
External command function
selection
3: Skip request
3
0
62
212
362
512
Pr.40
Positioning complete signal output time
Set the output time of the positioning complete signal [X14, X15, X16, X17] output
from the QD75.
A positioning completes when the specified dwell time has passed after the QD75
had terminated the output.
M
QD75
[Y10, Y11, Y12, Y13]
PLC
PLC CPU
Positioning start signal
Positioning
complete signal
[X14, X15, X16, X17]
Positioning
Positioning
start signal
Start complete
signal
BUSY signal
Positioning
complete signal
Positioning complete signal
(after dwell time has passed)
Output time
Positioning complete signal output time