12 CONTROL SUB FUNCTIONS

(3) Setting the dwell time during an OPR retry

The OPR retry function can perform such function as the dwell time using

"

Pr.57

Dwell time at OPR retry" when the reverse run operation is carried

out due to detection by the limit signal for upper and lower limits and when
the machine OPR is executed after the near point dog is turned OFF to stop
the operation.

"

Pr.57

Dwell time during OPR

"

is validated when the operation stops at

the "A" and "B" positions in the following drawing. (The dwell time is the
same value at both positions "A" and "B".)

Machine OPR
executed again

Stop by near-point
dog OFF

Stop by limit
signal detection

Reverse run operation
after limit signal detection

B

OP

Pr. 44 OPR direction

Machine OPR start

A

Limit signal OFF

Near-point dog

Zero signal

Fig. 12.3 Setting the dwell time during an OPR retry