[2] Precaution during control

(1) When changing the speed during continuous path control, the speed change

will be ignored if there is not enough distance remaining to carry out the
change.

(2) A warning "Deceleration/stop speed change (warning code: 500)" occurs

and the speed cannot be changed in the following cases.

(The value set in "

Cd.13

Positioning operation speed override" is validated

after a deceleration stop.)

During deceleration by a stop command

During automatic deceleration during positioning control

(3) When the speed is changed during interpolation control, the required speed

is set in the reference axis.

(4) When deceleration is started by the override function, the deceleration start

flag does not turn ON.

[3] Setting the override function

The following shows the data settings and sequence program example for setting

the override value of axis 1 to "200%".
(1) Set the following data. (Use the start time chart shown in section (2) below

as a reference, and set using the sequence program shown in section (3).)

Buffer memory address

Setting item

Setting

value

Setting details

Axis

1

Axis

2

Axis

3

Axis

4

Cd.13

Positioning
operation speed
override

200

Set the new speed as a percentage (%).

1513 1613 1713 1813

Refer to Section 5.7 "List of control data" for details on the setting details.

(2) The following shows a time chart for changing the speed using the override

function.

Cd. 13 Positioning operation
speed override

V

t

Dwell time

200

BUSY signal

Error detection signal

PLC READY signal

Positioning start signal

Positioning complete signal

QD75 READY signal

Start complete signal

[Y10]

[Y0]

[X0]

[X10]

[XC]

[X14]

[X8]

Fig. 12.29 Time chart for changing the speed using the override function