beautypg.com

Melsec-q, 3 specifications and functions – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 51

background image

3 - 3

MELSEC-Q

3 SPECIFICATIONS AND FUNCTIONS

Model

Item

QD75P1

1

QD75D1

QD75P2

1

QD75D2

QD75P4

1

QD75D4

1-axis linear control

6

1-axis speed control

6

2-axis linear interpolation control (Composite speed)

7

2-axis linear interpolation control (Reference axis speed)

7

2-axis circular interpolation control

7

2-axis speed control

6

3-axis linear interpolation control (Composite speed)

7

3-axis linear interpolation control (Reference axis speed)

7

3-axis speed control

6

4-axis linear interpolation control

7

Starting time (ms) 3

4-axis speed control

7

Factors in starting time extension

The following times will be added to
the starting time in the described
conditions:
• S-pattern acceleration/

deceleration is selected:

0.5

• Other axis is in

operation:

1.5

• During continuous

positioning control:

0.2

• During continuous path

control:

1.0

External wiring connection system 40-pin connector

Applicable wire size

0.3 mm

2

(for A6CON1 or A6CON4), AWG #24 (for A6CON2)

Applicable connector for external
device

A6CON1, A6CON2, A6CON4 (sold separately)

Max. output pulse

QD75P1, QD75P2, QD75P4 : 200kpps
QD75D1, QD75D2, QD75D4 : 1Mpps

Max. connection distance between
servos

QD75P1, QD75P2, QD75P4 : 2m
QD75D1, QD75D2, QD75D4 : 10m

Internal current consumption
(5VDC)

QD75P1 : 0.40A
QD75D1 : 0.52A

QD75P2 : 0.46A
QD75D2 : 0.56A

QD75P4 : 0.58A
QD75D4 : 0.82A

Flash ROM write count

Max. 100000 times

No. of occupied I/O points

32 points (I/O assignment: 32 points for intelligent function module)

Outline dimensions

98 (H)

×

27.4 (W)

×

90 (D) mm

Weight

0.15 kg

0.15 kg

0.16 kg

1: QD75P represents the open collector output system, and QD75D represents the differential driver output system.

3: Using the "Pre-reading start function", the virtual start time can be shortened. (For details, refer to Section 12.7.8 "Pre-reading start

function".

Differential driver common terminal specifications(QD75D1, QD75D2,

QD75D4 only)

Applicable wire size

12AWG

Solid wire: 0.2 to 0.8 mm

2

2 pcs.

Rated multiple wire
connection size

Stranded wire: 0.2 to 0.8 mm

2

2 pcs.

Screw tightening torque

0.5N • m