beautypg.com

17 speed-position switching control (abs mode), Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 390

background image

9 - 90

MELSEC-Q

9 MAJOR POSITIONING CONTROL

9.2.17 Speed-position switching control (ABS mode)

In case of "speed-position switching control (ABS mode)" ("

Da.2

Control system" =

Forward run: speed/position, Reverse run: speed/position), the pulses of the speed set

in "

Da.8

Command speed" are kept output in the axial direction set to the positioning

data. When the "speed-position switching signal" is input, position control to the

address set in "

Da.6

Positioning address/movement amount" is exercised.

"Speed-position switching control (ABS mode)" is available in two different types:

"forward run: speed/position" which starts the axis in the forward run direction and

"reverse run: speed/position" which starts the axis in the reverse run direction.

"Speed-position switching control (ABS mode)" is valid only when " Pr.1 Unit setting"

is "2: degree".

Pr.1

Unit setting

Speed-position
function selection

mm

inch

degree

pulse

INC mode

ABS mode

: Setting allowed,

: Setting disallowed (If setting is made, an error (error code: 935) will occur when the PLC

READY signal (Y0) turns ON.)

Use the detailed parameter 1 "

Pr.150

Speed-position function selection" to choose

"speed-position switching control (ABS mode)".

Buffer memory address

Setting item

Setting

value

Setting details

Axis 1

Axis 2

Axis 3

Axis 4

Pr.150

Speed-
position
function
selection

2

Speed-position switching control
(ABS mode)

34

184

334

484

If the set value is other than 0 and 2, it is regarded as 0 and operation is performed in the INC

mode.
For details of the setting, refer to Section 5.2 "List of parameters".

Switching over from speed control to position control

(1) The control is switched over from speed control to position control by the

external signal "speed-position switching signal".

(2) Besides setting the positioning data, the "

Cd.24

Speed-position switching

enable flag" must also be turned ON to switch over from speed control to

position control. (If the "

Cd.24

Speed-position switching enable flag" turns

ON after the speed-position switching signal turns ON, the control will continue
as speed control without switching over to position control. Only position

control will be carried out when the "

Cd.24

Speed-position switching enable

flag" and speed-position switching signal are ON at the operation start.)